Electra DCI 80 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Wärmepumpen Electra DCI 80 herunter. For Model 09/12 Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Presented By : Yossi Emquies

ANCOMPANY‹#›HDD/HED Training Presentation Presented By : Yossi EmquiesJan 12th2011

Seite 2 - Product Description

ANCOMPANY‹#›Intermediate Wiring ConnectionINDOOROUTDOORINDOOR 09/12OUTDOOR 09/12/18/24INDOOR 18/24

Seite 3 - Product Range Appearance

ANCOMPANY‹#›IDU Main Display RUN INDICATOR 1.Lights up when the Air Conditioner is connected to power and the mode is STBY. 2.When the unit is turned

Seite 4 - Main Key Features

ANCOMPANY‹#›RCO8-A Controller Main FunctionsMain Functions- Choose the operating mode (Heating-Dry-Fan or Automatic mode). - Increase or decrease the

Seite 5 - Specifications

ANCOMPANY‹#›Refrigerant Diagram(Model 09)

Seite 6 - Out Line Dimensions

ANCOMPANY‹#›Refrigerant Diagram(Model 12)

Seite 7

ANCOMPANY‹#›Refrigerant Diagram(Model 18)

Seite 8 - TECHNICAL ASPECTS

ANCOMPANY‹#›Refrigerant Diagram(Model 24)

Seite 9 - Installation

ANCOMPANY‹#›Wiring Diagram IDUINDOOR- 09/12INDOOR- 18/24

Seite 10 - INDOOR 18/24

ANCOMPANY‹#›Wiring Diagram ODUOUTDOOR- 09/12OUTDOOR- 18/24* EEV is only for Model 24

Seite 11 - IDU Main Display

ANCOMPANY‹#›IDU PCB Main Inputs and Outputs Layout (Indoor Model 09/12)Indoor controller of model 09/12IDU DisplayIDU Main Board* Model 09/12 use simi

Seite 12

ANCOMPANY‹#›Product Description The HDD/HED series is a DCI monosplit wall-mounted air conditionerdesigned mainly for residential applications.The O

Seite 13 - Refrigerant Diagram

ANCOMPANY‹#›IDU PCB Main Inputs and Outputs Layout (Indoor Model 09/12)Indoor Main Board of model 09/12PG motor powerPG motor feedbackICTRATTo Display

Seite 14

ANCOMPANY‹#›IDU PCB Main Inputs and Outputs Layout (Indoor Model 18/24)Indoor controller of model 18/24IDU DisplayIDU Main Board* Model 18/24 use simi

Seite 15

ANCOMPANY‹#›IDU PCB Main Inputs and Outputs Layout (Indoor Model 18/24)Indoor Main Board of model 18/24Model PlugICT,RATTo DisplayPG motor FeedbackLou

Seite 16

ANCOMPANY‹#›ODU PCB Main Inputs and Outputs Layout (Outdoor 09/12)Outdoor controller of model 09/12 PFC ReactorEMI Filter* Model 09/12 use similar con

Seite 17 - Wiring Diagram IDU

ANCOMPANY‹#›ODU PCB Main Inputs and Outputs Layout (Outdoor 09/12)ODU Main Board of model 09/12To EMI FilterSensor set(CTT+OCT+OAT)OLPFan motorAC-INTo

Seite 18 - Wiring Diagram ODU

ANCOMPANY‹#›ODU PCB Main Inputs and Outputs Layout (Outdoor 18/24)Outdoor controller of model 18/24 – Flat PCB combines Main Board and EMI Filter toge

Seite 19

ANCOMPANY‹#›ODU PCB Main Inputs and Outputs Layout (Outdoor 18/24)Outdoor controller of model 18/24OLPSensor setCTT+OCT+OATEEVOFANTo DC Compressor(U/V

Seite 20 - (Indoor Model 09/12)

ANCOMPANY‹#›Other issues we need to know 1. Compressor:• Model 09/12 use the same one compressor of Single Rotary type. • Model 18/22 use the same on

Seite 21

ANCOMPANY‹#›Main Control Functions

Seite 22 - Indoor Main Board of model

ANCOMPANY‹#›Compressor Target Speed Settings PI.  TIPTLoadConstConst**intSetPoRoomTempTProportionalPartIntegrativePartTakes the effect of thea

Seite 23 - EMI Filter

ANCOMPANY‹#›Product Range AppearanceAirwell- HDD 009/012Johnson- DDH 009/012Airwell- HED 009/012Electra-JED 009/012Airwell- HDD 018Johnson- DDH 018Air

Seite 24 - ODU Main Board of model 09/12

ANCOMPANY‹#›Compressor Min and Max Frequencies ModeMinimum Frequency (MinFreq)Maximum Frequency (MaxFreq)09 12 18 24See following tableCooling 16 16 1

Seite 25 - (Outdoor 18/24)

ANCOMPANY‹#›Indoor Fan Control Turbo FunctionAuto Fan ModeUnder Turbo mode, IFAN will operate at Super High speed. And outdoor will operate at higher

Seite 26

ANCOMPANY‹#›Cooling Mode/ Dry Mode If RAT≥SPT, the unit starts cooling operation. In this case, the compressor and outdoor fan will operate and the i

Seite 27

ANCOMPANY‹#›Heating Mode If RAT<SPT+1.5 AND for certain period, the unit will operate in heating mode. The compressor, outdoor fan and 4-way valve

Seite 28 - Main Control Functions

ANCOMPANY‹#›Heating Mode Models 9/12Models 18/24Anti-cold air function:When starting the heating mode, anti-cold air function will be activated and in

Seite 29 -  TIPTLoad

ANCOMPANY‹#›Auto Mode/ Fan Mode In AUTO mode, the system selects the running mode (COOL/HEAT/FAN) automatically according to the room temperature. The

Seite 30 - Maximum Frequency

ANCOMPANY‹#›Sleep Mode

Seite 31 - Indoor Fan Control

ANCOMPANY‹#›Clean Function and I Feel ModeClean FunctionI Feel -Function

Seite 32 - Cooling Mode/ Dry Mode

ANCOMPANY‹#›Protections There are 4 main protection levels:1. Normal (Norm) – unit operate normally.2. Stop Rise (SR) – compressor frequency can not b

Seite 33 - Heating Mode

ANCOMPANY‹#›Protections IDU Coil Overheating protection (heating mode):During heating operation, the signals being sent from the indoor unit allows th

Seite 34

ANCOMPANY‹#›Main Key Features DC inverter technology. R410A models. Microprocessor control equipped with indoor 2 segment display . High COP, Ener

Seite 35 - Auto Mode/ Fan Mode

ANCOMPANY‹#›Compressor Over Current Protection:Model 09/12: Compressor will stop when AC current reaches 14.0A for continuously 2.5s.Model 18/22: Comp

Seite 36 - Sleep Mode

ANCOMPANY‹#›Deicing Procedure:This protection is for Heat Pump OnlyThis protection is carried out by the cooling cycle (reverse cycle). The defrosting

Seite 37 - I Feel -Function

ANCOMPANY‹#›9/12 Deicing Procedure:Protections18/24 models:

Seite 38 - Protections

ANCOMPANY‹#›ProtectionsAC Voltage Drop:During compressor operation, the system will stop in case of an AC voltage malfunction the unit will resume it

Seite 39

ANCOMPANY‹#›Refrigerant Control Concept For Models 09/12/18 capillary method is used.EEV is used only on Model 24:1. EEV operation after power-on: Whe

Seite 40

ANCOMPANY‹#›Test Mode Procedure Models 9/12:

Seite 41

ANCOMPANY‹#›Test Mode Procedure Models 18/24:

Seite 42

ANCOMPANY‹#›Forced Cooling Mode18/24 Models Only:

Seite 43

ANCOMPANY‹#›Error Failure Code list and Probable Cause The Fault codes can be displayed by 2*7 segments (on IDU Display board)Blinking of IDU LEDs (RU

Seite 44 - Refrigerant Control Concept

ANCOMPANY‹#›Error Failure Code list and Probable Cause Indoor indicators Outdoor indicators Failure Possible Reasons/Corrective actions2* 7 segmentsLE

Seite 45 - Test Mode Procedure

ANCOMPANY‹#›Specifications

Seite 46

ANCOMPANY‹#›Error Failure Code list and Probable Cause Indoor indicators Outdoor indicators Failure Possible Reasons/Corrective actions2* 7 segmentsLE

Seite 47 - Forced Cooling Mode

ANCOMPANY‹#›Error Failure Code list and Probable Cause Indoor indicators Outdoor indicators Failure Possible Reasons/Corrective actions2* 7 segmentsLE

Seite 48 - Leds Status:

ANCOMPANY‹#›Error Failure Code list and Probable Cause Indoor indicators Outdoor indicators Failure Possible Reasons/Corrective actions2* 7 segmentsLE

Seite 49 - Sample of 18/24

ANCOMPANY‹#›Error Failure Code list and Probable Cause Indoor indicators Outdoor indicators Failure Possible Reasons/Corrective actions2* 7 segmentsLE

Seite 50

ANCOMPANY‹#›END

Seite 51

ANCOMPANY‹#›Out Line Dimensions(Model 09/12)Indoor Unit Outdoor Unit

Seite 52

ANCOMPANY‹#›Out Line Dimensions(Model 18/24)Indoor UnitOutdoor Unit

Seite 53

ANCOMPANY‹#›TECHNICAL ASPECTS

Seite 54

ANCOMPANY‹#›Installation MAXIMUM PIPES LENGTH & HEIGHTNOM. CAPACITY (kBtu/h)TUBES O.D. LENGTH (A)HEIGHT(B)PRECHARGELENGTHADDITIONAL CHARGE09 1/4”

Kommentare zu diesen Handbüchern